Short Description:

RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512  Model: RCAC25FS Structure: Diaphragm Working-pressure: 0.3--0.8MPa Ambient Temperature: -5 ~55 Relative Humidity: < 85 % Working Medium: Clean Air Voltage: AC220V DC24V Diaphragm Life: One Million cycles Port Size: 1" Construction Body: Aluminium (diecast) Ferrule: 304 SS Armature: 430FR SS Seals: Nitrile or Viton (reinforced) Spring: 304 SS Screws: 302 SS Diaphragm Material: NBR / Viton Kinds different typ...


Product Detail

Product Tags

Related Video

Feedback (2)

With this motto in mind, we've turn into one of quite possibly the most technologically innovative, cost-efficient, and price-competitive manufacturers for Australia Type Pulse Valve, Right Angle Solenoid Pulse Jet Valve, Threaded Pulse Valve, As a key enterprise of this industry, our corporation makes attempts to become a leading supplier, depending on the faith of expert excellent & throughout the world assistance.
Factory Outlets Male Bnc Connector - RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512 – Green Power Detail:

RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512 

Model: RCAC25FS
Structure: Diaphragm
Working-pressure: 0.3--0.8MPa
Ambient Temperature: -5 ~55
Relative Humidity: < 85 %
Working Medium: Clean Air
Voltage: AC220V DC24V
Diaphragm Life: One Million cycles
Port Size: 1"

70.

Construction
Body: Aluminium (diecast)
Ferrule: 304 SS
Armature: 430FR SS
Seals: Nitrile or Viton (reinforced)
Spring: 304 SS
Screws: 302 SS
Diaphragm Material: NBR / Viton

Kinds different type pulse valve for choose

 

 

IMG_5497

Installation
1. Prepare supply and blow tube pipes to suit valve specification. Avoid installing
valves underneath the tank.
2. Ensure tank and pipes avoid dirt, rust or other particulate.
3. Make sure air source is clean and dry.
4, When mount valves to inlet pipes and outlet to the baghouse, ensuring no excess thread
sealant can enter the valve itself. Keep clear in the valve and pipe.
5. Make electrical connections from solenoid to the controller or connect RCA pilot port to pilot valve
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.

Type Orifice Port Size Diaphragm KV/CV
CA/RCA20T 20 3/4" 1 12/14
CA/RCA25T 25 1" 1 20/23
CA/RCA35T 35 1 1/4" 2 36/42
CA/RCA45T 45 1 1/2" 2 44/51
CA/RCA50T 50 2" 2 91/106
CA/RCA62T 62 2 1/2" 2 117/136
CA/RCA76T 76 3 2 144/167

K2512 nitrile membrane suit for 1" goyen pulse valve RCA-25FS, CA-25FS, RCA-25DD, CA-25DD, RCA-25T, CA-25T21

Good quality imported diaphragm shall be selected and used for all the valves, with each part checked in each manufacturing procedure, and put into the assembly line conforming to all the procedures. Ever finished valve shall be taken blowing test.
Diaphragm repair kits suit for DMF series dust collector diaphragm valve
Temperature Range: -40 – 120C ( Nitrile material diaphragm and seal), -29 – 232C (Viton material diaphragm and seal)

Loading time: 7-10 days after payment received
Warranty: Our pulse valve warranty is 1.5 year, all valves comes with basic 1.5 year sellers warranty, if item defective in 1.5 year, We will offer replacement without extra charger(including shipping fee) after we receive the defective products.

Deliver
1. We will arrange deliver immediately after payment when we have storage.
2. We will prepare the goods after confirmed in the contract on time, and deliver ASAP follow the contract exactly when the goods are customized
3. We have a variety of ways to send goods, such as by sea, by air, express as DHL, Fedex, TNT and so on. We also accept deliver arranged by customers.


Product detail pictures:

Factory Outlets Male Bnc Connector - RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512 – Green Power detail pictures

Factory Outlets Male Bnc Connector - RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512 – Green Power detail pictures

Factory Outlets Male Bnc Connector - RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512 – Green Power detail pictures


Related Product Guide:
In focus: a 1927 ‘Stroh’ violin by Buffa Baretti | Focus | Brass Quick Connect Couplings
Jet power adds screeching speed to bicycle travel | Pilot

We'll make every effort and hard work to be superb and excellent, and speed up our steps for standing inside the rank of intercontinental top-grade and high-tech enterprises for Factory Outlets Male Bnc Connector - RCAC25FS goyen remote pilot 1 inch inlet flanged pulse valve, diaphragm kit K2512 – Green Power, The product will supply to all over the world, such as: Libya, Iran, Tajikistan, Our items are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
  • The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By David from Benin - 2015.11.06 10:04
    High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Alexandra from Serbia - 2016.05.02 18:28
    WhatsApp Online Chat !